SPAN BIOTECH LTD.

Professional Designer for IVD Enterprises of the World

Sales & Support
Request A Quote - Email
Select Language
English
French
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsInfectious Disease Rapid Tests

One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P)

One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P)

One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P)
One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P)

Large Image :  One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P) Get Best Price

Product Details:
Place of Origin: China
Brand Name: SPAN
Certification: ISO CE
Model Number: HIV
Payment & Shipping Terms:
Minimum Order Quantity: 100 tests
Price: U$0.28-U$0.38
Packaging Details: 30 tests/box
Delivery Time: within 3-5 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000000 pcs per month
Detailed Product Description
Package: 30 Tests/box Specificity: 100%
Sensitivity: 100%

 

One Step HIV1/2/O Tri-Line Rapid Test Cassette (W/S/P)
 
INTENDED USE
The HIV-1/2 Rapid Screen Test (RST) is a qualitative test for the detection of antibodies to Human Immunodeficiency Virus type 1 and 2(HIV-1/2) in human serum/plasma and whole blood. It is considered as an initial screening test for HIV-1/2 antibodies. All positive specimens must be confirmed with Western Blot or other qualified EIA.
 
PRECAUTION

  • For in vitro diagnostic uses only.
  • All patient samples should be treated as if capable of transmitting diseases.
  • Do not use test kit beyond expiration date.
  • Icteric, lipemic, hemolysed, heat treated and contaminated sera may cause erroneous results.

SUMMARY AND EXPLANATION OF THE TEST 

It has been shown that the acquired immunodeficiency syndrome (AIDS) is caused by viruses transmitted by sexual contact, transfusion, use of contaminated blood products and sharing contaminated needles. HIV-1 and HIV-2 viruses have been isolated from patients with AIDS and AIDS-related complex (ARC), high-risk persons for AIDS. HIV-1 and HIV-2 viruses delete T helper cells, a subpopulation of T cells for body defense, thus causing AIDS patients susceptible to opportunistic infections and developing malignant tumors. The incidence of specific antibodies to HIV-1/2 is high in AIDS, ARC and persons with high risk for AIDS. The HIV-1/2 Rapid Screen Test is designed to detect antibodies to HIV-1/2 in AIDS patients, ARC or high risk persons and identify any potential donors carrying these antibodies in serum specimens.
 
PRINCIPLE
HIV-1/2 RST is a chromatographic immunoassay (CIA) for the detection of antibodies to HIV-1/2 in human serum/plasma and whole blood. HIV-1/2 specific antigens are precoated onto membrane as a capture reagent on the test region. During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with HIV-1/2 specific antigens. Antibodies to HIV-1/2, if present, a red colored band will develop on the membrane in proportion to the amount of HIV-1/2 antibodies present in the specimen. Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, red colored band in the control region will always appear regardless the presence of antibodies to HIV-1/2.
 
MATERIALS SUPPLIED

1. One pouched cassette with desiccant.

2. Blood diluent in a dropper bottle, stored at 2-8°C.

3. One piece of operating instruction.

 

MATERIALS NOT PROVIDED BUT REQUIRED

  • Specimen collection container, either plastic or class.
  • Timer.
  • Disposable gloves.

 
SPECIMEN COLLECTION AND PREPARATION
 
Fingerstick Specimens(Whole Blood)

  • Clean the area to be lanced with an alcohol swab.
  • Squeeze the end of the fingertip and pierce it with a sterile lancet.
  • Wipe away the first drop of blood with sterile gauze or cotton.
  • Use micropipet to obtain about 100 ul fresh blood .

Plasma

  • Have a certified phlebotomist collect whole blood into a purple, blue or green top collection tube (containing EDTA, citrate or heparin, respectively) by veinpuncture.
  • Separate the plasma by centrifugation.
  • Carefully withdraw the plasma for testing, or label and store it at 2-8°C for up to two weeks. Plasma may be frozen at -20°C for up to one year.

Serum

  • Have a certified phlebotomist collect whole blood into a red top collection tube (containing no anticoagulants) by veinpuncture.
  • Allow the blood to clot.
  • Separate the serum by centrifugation.
  • Carefully withdraw the serum for testing or label and store it at 2-8°C for up to two weeks. Serum may be frozen at -20°C for up to one year.

ASSAY PROCEDURE
Add 1 drop (1 drop = 35µl) of sample (whole blood/serum/plasma) into the sample well. After all samples completely absorbed, add 1 drop of diluent. Observe the result in 5-15 minutes.

 

QUALITY CONTROL
An internal procedural control is included in the test. red line will appears in the control region (C).
 
INTERPRETATION OF RESULTS 
Negative: No apparent band in the test region (1 and 2), Only one red band appears in the control region (C). This indicates that no HIV1/2 antibodies have been detected.
Positive: In addition to the band in the control region (C), other one or two red bands will appear in the test region (1 and 2). This indicates that the specimen contains HIV1/2 antibodies.
Invalid: If no band appears in the control region(C), regardless of the presence or absence of line in the test region (T). It indicates a possible error in performing the test. The test should be repeated using a new device

 

STORAGE AND STABILITY
Store HIV-1/2 Rapid Screen Test at temperature ranges 4-30 °C in the sealed pouch. Refer to the expiration date for stability. Do not freeze.
 
LIMITATION

1.The test is to be used for the qualitative detection of antibodies to HIV.

2.A negative result does not rule out infection by HIV because the antibodies to HIV may be absent or may not be present in sufficient quality to be detected at early stage of infection.

3.A positive result, even a weak positive, must be verified with a confirmation test.

4.As with all diagnostic tests, the result must be correlated with clinical findings. If the test result is negative and suspicion still exists, additional follow-up testing using other clinical methods is recommended.

 

 

Contact: Rebecca Yan

Tel: +86(755)89589611

Fax: +86(755)89580096

Cell Phone:+8613417551798(WhatsApp)

Web: www.spanbio.com

Email: rebecca@spanbio.com

 

 
 
 

 

Contact Details
SPAN BIOTECH LTD.

Contact Person: Ms. Anna Lee

Tel: +86-755-89589611

Fax: 86-755-89580096

Send your inquiry directly to us
www.spanbio.com