SPAN BIOTECH LTD.

Professional Designer for IVD Enterprises of the World

Sales & Support
Request A Quote - Email
Select Language
English
French
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsDrug of Abuse Tests

One-Step Cocaine Test Cassette

One-Step Cocaine Test Cassette

One-Step Cocaine Test Cassette
One-Step Cocaine Test Cassette

Large Image :  One-Step Cocaine Test Cassette Get Best Price

Product Details:
Place of Origin: China
Brand Name: SPAN
Certification: ISO CE
Model Number: RA0506
Payment & Shipping Terms:
Minimum Order Quantity: 100 tests
Price: Negotiable
Packaging Details: 20 tests/box
Delivery Time: within 3-5 working days(depends on your quantity)
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000000 pcs per month
Detailed Product Description
Package: 20 Tests/box Specificity: 100%
Sensitivity: 100%

One-Step Cocaine Test Cassette

Package insert for Cocaine Test Cassette. This Instruction Sheet is for testing of Cocaine. For professional and in vitro diagnostic use only.

Intended Use The COC One-Step Cocaine Test Cassette is a lateral flow chromatographic immunoassay for the qualitative detection of Cocaine in urine at the cut-off concentrations of 300ng/ml. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used. Summary Cocaine is a potent central nervous system (CNS) stimulant and a local anesthetic. Initially, it brings about extreme energy and restlessness while gradually resulting in tremors, over-sensitivity and spasms. In large amounts, cocaine causes fever, unresponsiveness, and difficulty in breathing and unconsciousness. Cocaine is often self-administered by nasal inhalation, intravenous injection and free-base smoking. It is excreted in the urine in a short time primarily as Benzoylecgonine. Benzoylecgonine, a major metabolite of cocaine, has a longer biological half-life (5-8 hours) than cocaine (0.5-1.5 hours), and can generally be detected for 24-48 hours after cocaine exposure. The COC One-Step Cocaine Test Cassette yields a positive result when the cocaine metabolite in urine exceeds 300ng/ml. This is the suggested screening cut-off for positive specimens set by the Substance Abuse and Mental Health Services Administration (SAMHSA, USA). Principle The COC One-Step Cocaine Test Cassette is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against their respective drug conjugate for binding sites on their specific antibody. During testing, a urine specimen migrates upward by capillary action. A drug, if present in the urine specimen below its cut-off concentration, will not saturate the binding sites of its specific antibody. The antibody will then react with the drug-protein conjugate and a visible colored line will show up in the test line region of the specific drug strip. The presence of drug above the cut-off concentration will saturate all the binding sites of the antibody. Therefore, the colored line will not form in the test line region. A drug-positive urine specimen will not generate a colored line in the specific test line region of the strip because of drug competition, while a drug-negative urine specimen will generate a line in the test line region because of the absence of drug competition. To serve as a procedural control, a colored line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred. Warnings and Precautions  For in vitro diagnostic use only.  For healthcare professionals and professionals at point of care sites.  Do not use after the expiration date.
 Please read all the information in this leaflet before performing the test.  The test panel should remain in the sealed pouch until use.  All specimens should be considered potentially hazardous and handled in the same manner as an infectious agent.  The used test panel should be discarded according to federal, state and local regulations. Composition The test contains a membrane strip coated with Cocaine -protein conjugates on the test line, a goat-anti-mouse IgG polyclonal antibody on the control line, and a dye pad which contains colloidal gold-monoclonal antibody specific to Cocaine. Each box contains test panels and package insert. Storage and Stability  Store as packaged in the sealed pouch at room temperature (2-30℃ or 36-86 ℉).The kit is stable within the expiration date printed on the labeling.  Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration. Additional Special Equipment Specimen collection containerTimerExternal controls Specimen  The urine specimen must be collected in a clean and dry container. Urine collected at any time of the day may be used. Urine specimens exhibiting visible precipitates should be centrifuged, filtered, or allowed to settle to obtain a clear supernatant for testing.  Urine specimens may be stored at 2-8°C for up to 48 hours prior to testing. For prolonged storage, specimens may be frozen and stored below -20°C. Frozen specimens should be thawed and mixed well before testing. Test Procedure Allow the test and urine samples to equilibrate to room temperature (15-30℃or 59-86℉) prior to testing. 1. Remove the test cassette from the sealed pouch. 2. Hold the dropper vertically and transfer 3 full drops(approx. 100l) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below. 3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.

Interpretation of Results Negative:*Two lines appear. One red line should be in the control region (C), and another apparent red or pink line adjacent should be in the test region (T). This negative result indicates that the drug concentration is below the detectable level. *NOTE: The shade of red in the test line region (T) will vary, but it should be considered negative whenever there is even a faint pink line. Positive: One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the drug concentration is above the detectable level. Invalid: Control line fails to appear. Insufficient specimen volume or incorrect
procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test panel. If the problem persists, discontinue using the lot immediately and contact your local distributor. Quality Control A procedural control is included in the test. A red line appearing in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique. Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance. Limitations  The COC One-Step Cocaine Test Cassette provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography and mass spectrometry (GC/MS) is the preferred confirmatory method.  There is a possibility that technical or procedural errors, as well as other interfering substances in the urine specimen may cause erroneous results.  Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.  A Positive result does not indicate level or intoxication, administration route or concentration in urine.  A Negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.  Test does not distinguish between drugs of abuse and certain medications.  A positive test result may be obtained from certain foods or food supplements. Performance Characteristics Accuracy A side-by-side comparison was conducted using the COC One-Step Cocaine Test Cassette and commercially available drug rapid tests. Testing was performed on approximately 300 specimens per drug type previously collected from subjects presenting for Drug Screen Testing. Presumptive positive results were confirmed by GC/MS. The following compounds were quantified by GC/MS and contributed to the total amount of drugs found in presumptive positive urine samples tested. Test Compounds Contributed to the Totals of GC/MS COC Benzoylecgonine The following results are tabulated from these clinical studies: %Agreement with Commercial Kit
%Agreement with GC/MS COC COC Positive Agreement 96% Positive Agreement 98% Negative Agreement 100% Negative Agreement 95% Total Results 98% Total Results 96% Forty (40) clinical samples were run using the COC One-Step Cocaine Test Cassette by an untrained operator at a Professional Point of Care site. Based on GC/MS data, the operator obtained statistically similar Positive Agreement, Negative Agreement and Overall Agreement rates as trained Laboratory personnel. Precision A study was conducted at three physician offices by untrained operators using three
different lots of product to demonstrate the within run, between run and between operator precision. An identical panel of coded specimens, containing drugs at the concentration of ± 50% and ± 25% cut-off level, was labeled as a blind and tested at each site. The results are given below: Benzoylecgonine conc.(ng/ml) n per site Site A Site B Site C - + - + - + 0 15 15 0 15 0 15 0 150 15 15 0 14 1 15 0 225 15 10 5 7 8 10 5 375 15 0 15 0 15 0 15 450 15 0 15 0 15 0 15

Analytical Sensitivity A drug-free urine pool was spiked with drugs at concentrations listed. The results are summarized below: Drug concentration Cut-off Range n COC - + 0% Cut-off 30 30 0 -50% Cut-off 30 30 0 -25% Cut-off 30 30 0 Cut-off 30 3 27 25% Cut-off 30 0 30 50% Cut-off 30 0 30

Analytical Specificity The following table lists the concentration of compounds (ng/ml) that are detected positive in urine by The COC One-Step Cocaine Test Cassette at 3-5 minutes. Cocaine (COC) Concentration(ng/ml) Benzoylecgonine 300 Cocaine HCl 780 Cocaethylene 12,500 Ecgonine HCl 32,000

Effect of Urinary Specific Gravity Fifteen (15) urine samples of normal, high, and low specific gravity ranges (1.000-1.037) were spiked with drugs at 50% below and 50% above cut-off levels respectively. The COC One-Step Cocaine Test Cassette was tested in duplicate using fifteen drug-free urine and spiked urine samples. The results demonstrate that varying ranges of urinary specific gravity does not affect the test results. Effect of the Urinary pH The pH of an aliquoted negative urine pool was adjusted to a pH range of 5 to 9 in 1 pH unit increments and spiked with drugs at 50% below and 50% above cut-off levels. The spiked, pH-adjusted urine was tested with the COC One-Step Cocaine Test Cassette. The results demonstrate that varying ranges of pH does not interfere with the performance of the test. Cross-Reactivity A study was conducted to determine the cross-reactivity of the test with compounds in either drug-free urine or Cocaine positive urine. The following compounds show no cross-reactivity when tested with the COC One-Step Cocaine Test Cassette at a concentration of 100µg/ml. Non Cross-Reacting Compounds

Acetaminophen Acetophenetidin
N-Acetylprocainamide Acetylsalicylic acid Aminopyrine Amoxicillin Ampicillin L-Ascorbic acid Apomorphine Aspartame Atropine Benzilic acid Benzoic acid Benzphetamine* Bilirubin D/L-Brompheniramine Caffeine Cannabidol Chloralhydrate Chloramphenicol Chlorothiazide D/L-Chloropheniramine Chlorpromazine Chloroquine Cholesterol Clonidine Cortisone L-Cotinine Creatinine Deoxycorticosterone Dextromethorphan Diclofenac Diflunisal Digoxin Diphenhydramine Ecgonine methyl ester L -Ψ-Ephedrine β-Estradiol Estrone-3-sulfate Ethyl-p-aminobenzoate [1R,2S] (-) Ephedrine L(–)-Epinephrine Erythromycin Fenoprofen Furosemide Gentisic acid Hemoglobin Hydralazine Hydrochlorothiazide Hydrocortisone O-Hydorxyhippuric acid p-Hydroxyamphetamine p-Hydroxytyramine Ibuprofen Iproniazid D/L-Isoproterenol Isoxsuprine Ketamine Ketoprofen Labetalol Loperamide Meperidine Meprobamate Methoxyphenamine Methylphenidate Nalidixic acid Naloxone Naltrexone Naproxen Niacinamide Nifedipine Norethindrone D-Norpropoxyphene Noscapine D/L-Octopamine Oxalic acid Oxolinic acid Oxymetazoline Papaverine Penicillin-G Pentazocine hydrochloride Perphenazine Phenelzine Trans-2-phenylcyclo-propylamine hydrochloride L-Phenylephrine β-Phenylethylamine Phenylpropanolamine Prednisolone Prednisone D/L-Propranolol D-Propoxyphene D-Pseudoephedrine Quinacrine Quinine Quindine Ranitidine Salicylic acid Serotonin Sulfamethazine Sulindac Tetracycline Tetrahydrocortisone 3-acetate Tetrahydrozoline Tetrahydrocortisone 3 (β-D-glucuronide) Thiamine Thioridazine D/L-Tyrosine Tolbutamide Triamterene Trifluoperazine Trimethoprim Tryptamine D/L-Tryptophan Tyramine Uric acid Verapamil
Zomepirac *Parent compound only; metabolizes amphetamine and methamphetamine in urine. Bibliography 1. Baselt RC. Disposition of Toxic Drugs and Chemicals in Man. 6th Ed. Biomedical Publ., Davis, CA. 2002; 129. 2. FDA Guidance Document: Guidance for Premarket Submission for Kits for Screening Drugs of Abuse to be Used by the Consumer, 1997. 3. A Handbook of Drug and Alcohol Abuse, Gail Winger, Third Edition, Oxford Press, 1992, page 146. 4. Tietz NW. Textbook of Clinical Chemistry. W.B. Saunders Company. 1986; 1735. 5. Hawks RL, CN Chiang. Urine Testing for Drugs of Abuse. National Institute for Drug Abuse (NIDA), Research Monograph 73, 1986.












Index of Symbols Do not reuse For in vitro diagnostic use only Stored between 2-30℃ Consult instruction for use Caution Lot number Use by Contains sufficient for <n> tests
Keep away from sunlight
Keep dry
Manufacturer Do not use if package is damaged Authorized Representative in the European Community





Version No.:4.0 Effective Date: Feb. 24, 2012

 

 

 

 

Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.

 

Our mission:

 

  • Always best of all and always pay attention to innovation.
  • Special customized service tightly following customers’ requests.
  • Integrated excellent quality, competitive prices and super service together.

 

Rebecca Yan

 
Product Manager
Span Biotech Ltd.
Tel: +86(755)89589611
Cell Phone:+8618823462100(WhatsApp)
Web:www.spanbio.com

 

 

 

 

 

Contact Details
SPAN BIOTECH LTD.

Contact Person: Ms. Anna Lee

Tel: +86-755-89589611

Fax: 86-755-89580096

Send your inquiry directly to us
www.spanbio.com