SPAN BIOTECH LTD.

Professional Designer for IVD Enterprises of the World

Sales & Support
Request A Quote - Email
Select Language
English
French
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHot Sales

Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet

Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet

Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet
Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet

Large Image :  Salmonella Typhoid(S. typhi) IgG/IgM Rapid Test Uncut Sheet Get Best Price

Product Details:
Place of Origin: China
Brand Name: SPAN
Certification: S. typhi
Model Number: Typhoid
Payment & Shipping Terms:
Minimum Order Quantity: 50 sheets
Price: U$15/sheet
Packaging Details: 30 sheets/pouch
Delivery Time: within 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Supply Ability: Typhoid
Detailed Product Description
Specificity: 100%

One Step Typhiod IgG/IgM Rapid Test Uncut Sheet

 

INTENDED USE

The Typhoid IgG/IgM Rapid Test Device is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood, serum or plasma.

 

SUMMARY AND EXPLANATION OF THE TEST

Typhoid fever is caused by S. typhi, a Gram-negative bacterium. World-wide an estimated 17 million cases and 600,000 associated deaths occur annually1. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi2. Evidence of H. pylori infection also presents an increase risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gallbladder.

 The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the   interpretation of the Widal test3,4.

In contrast, the Typhoid IgG/IgM Rapid Test Device is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen5 thus to aid in the determination of current or previous exposure to the S. typhi.

 

TEST PRINCIPLE

The Typhoid IgG/IgM Rapid Test Device is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing recombinant S. typhoid H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (IgG and IgM bands) and a control band (C band). The IgM band is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, IgG band is pre-coated with reagents for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG.

When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette.  Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody, forming a burgundy colored IgM band, indicating a S. typhi IgM positive test result.

Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a burgundy colored IgG band, indicating a S. typhi IgG positive test result.

Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device.

 

REAGENTS AND MATERIALS PROVIDED

1. 25 Test Device with 25 dropper

2.Sample Diluent

3.One package insert (instruction for use)

 

MATERIALS REQUIRED BUT NOT PROVIDED

Clock or Timer

 

WARNINGS AND PRECAUTUIONS

1.Do not use after expiration date indicated on the package. Do not use the test if its foil pouch is damaged. Do not reuse tests.

2.The products should be treated as potentially infectious, and handled observing the usual safety precautions (do not ingest or inhale).

3.Avoid cross-contamination of specimens by using a new specimen collection container for each specimen obtained.

4.Do not eat, drink or smoke in the area where the specimens and kits are handled. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout the procedure and follow the standard procedures for proper disposal of specimens. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.

5.Do not interchange or mix reagents from different lots.

6.Humidity and temperature can adversely affect results.

7.The used testing materials should be discarded in accordance with local, state and/or federal regulations.

 

PREPARATION AND STORAGE INSTRUCTIONS

All reagents are ready to use as supplied. Store unused test devices unopened at 2°C-30°C.  The positive and negative controls should be kept at 2°C-8°C. If stored at 2°C-8°C, ensure that the test device is brought to room temperature before opening. The test device is stable through the expiration date printed on the sealed pouch. Do not freeze the kit or expose the kit over 30°C.

 

SPECIMEN COLLECTION AND HANDLING

Consider any materials of human origin as infectious and handle them using standard biosafety procedures.

 

Whole Blood specimens:

Collect blood specimen into a lavender, blue or green top collection tube (containing EDTA, citrate or heparin, respectively in Vacutainer®) by veinpuncture.

Plasma

Collect blood specimen into a lavender, blue or green top collection tube (containing EDTA, citrate or heparin, respectively in Vacutainer®) by veinpuncture. Separate the plasma by centrifugation. Carefully withdraw the plasma into new pre-labeled tube.

Serum

Collect blood specimen into a red top collection tube (containing no anticoagulants in Vacutainer®) by veinpuncture. Allow the blood to clot. Separate the serum by centrifugation. Carefully withdraw the serum into a new pre-labeled tube.

Test specimens as soon as possible after collecting. Store specimens at 2°C-8°C if not tested immediately.

Store specimens at 2°C-8°C up to 5 days. The specimens should be frozen at -20°C for longer storage.

Avoid multiple freeze-thaw cycles. Prior to testing, bring frozen specimens to room temperature slowly and mix gently. Specimens containing visible particulate matter should be clarified by centrifugation before testing. Do not use samples demonstrating gross lipemia, gross hemolysis or turbidity in order to avoid interference on result interpretation.

Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly.

If specimens are to be shipped, they should be packed in compliance with local regulations covering the transportation of etiologic agents.

 

 

Contact:Rebecca Yan

Tel: +86(755)89589611

Fax: +86(755)89580096

Cell Phone:+8613417551798(WhatsApp)

Web: www.spanbio.com

Email: rebecca@spanbio.com

 

Contact Details
SPAN BIOTECH LTD.

Contact Person: Ms. Anna Lee

Tel: +86-755-89589611

Fax: 86-755-89580096

Send your inquiry directly to us
www.spanbio.com